Performance Analysis of a Multisensor IoT System for Water Quality Surveillance at PDAM Makassar

Authors

  • Muhammad Syafaat Institut Teknologi Bacharuddin Jusuf Habibie
  • Jeffry Jeffry Institut Teknologi Bacharuddin Jusuf Habibie

DOI:

https://doi.org/10.31004/joecy.v5i3.4885

Keywords:

Monitoring System, Water Quality, Sensor, IoT, PDAM

Abstract

IoT-Based Water Monitoring System with Case Study of Makassar City PDAM is a tool made to provide convenience to PDAM (Regional Drinking Water Company) employees, especially at Makassar City PDAM, to determine the pH value of water, TDS value and NTU level value in water reservoirs using a water pH sensor, TDS sensor and LDR sensor which will be displayed on a website application via an internet network in the form of a graph. If the pH value read on the water pH sensor is pH 6.5-8.5, it can be declared that the water is in proper condition, if the ppm value read to the TDS sensor is 0-300 ppm, the water is declared proper and if the ppm value read to the LDR sensor is 0-25 NTU, the water is declared proper. the parameter accuracy rate of the pH Sensor is 94.74%, the TDS Sensor is 93.70%, while the Water Turbidity sensor has an accuracy rate of 85.31% so that the overall accuracy rate of this consumable water monitoring system is 91.25%.

References

Ahmed, S., Khan, M. A., & Rahman, M. (2024). IoT based real-time water quality monitoring system in water treatment plants (WTPs). Heliyon, 10(24), e12088.

Ardiansyah. (2016). Arduino-based water monitoring system (PDAM Patalassang case study). Gowa: UIN Alauddin Makassar.

Chen, L., Wang, X., & Li, Y. (2023). An Arduino-based water quality monitoring system using pH, temperature, turbidity, and TDS sensors. Sensors and Actuators A: Physical, 351, 114163.

Doni Puromo, A., Daud, A., & Selomo, M. (2014). Chemical and physical quality of Jeneberang river water as raw water for PDAM Makassar. Hasanuddin University, Makassar.

García-Vázquez, J. P., Rodríguez-Licea, M. A., Pérez-Pinal, F. J., & Núñez-Pérez, J. C. (2022). IoT-based water monitoring systems: A systematic review. Water, 14(22), 3621.

Ibrahim, H., Iqbal, T., AlMallahi, M. N., Abdelkareem, M. A., & Olabi, A. G. (2024). Internet of Things and citizen science as alternative water quality monitoring approaches and the importance of effective water quality communication. Journal of Environmental Management, 351, 119854.

Indonesian Minister of Health. (1990). Permenkes number: 416/MEN.KES/PER/IX/1990 concerning standards for the quality of drinking water.

Kumar, P., Singh, A., & Sharma, R. (2023). Design of a real-time water quality monitoring and control system using Internet of Things (IoT). Cogent Engineering, 9(1), 2143054.

Matić, B., Mikšić, L., Cigula, T., & Mahović Poljaček, S. (2021). Water quality monitoring with Arduino-based sensors. Chemosensors, 8(1), 6.

Mubarak, M. F., Daud, A., & Birawida, A. B. (2016). The quality of Jeneberang river water as raw water for PDAM Makassar city. Hasanuddin University, Makassar.

Downloads

Published

27-11-2025

How to Cite

Syafaat, M. ., & Jeffry, J. (2025). Performance Analysis of a Multisensor IoT System for Water Quality Surveillance at PDAM Makassar. Journal of Innovative and Creativity, 5(3), 33020–33025. https://doi.org/10.31004/joecy.v5i3.4885

Issue

Section

Articles